Abstract

A GC method is described for the simultaneous determination of triazines and phenylureas in aqueous samples by large volume injection with a Programmable Temperature Vaporisator injector (PTV) and ion trap detection (ITD). The analytical col- umn (DB 5MS, 30 m, 0.25 mm, 0.25 μm) is connected to a pre-column (DB 5MS, 5 m, 0.25 mm, 0.25 μm) via a cross piece valve (MCS) to prevent residual solvant vapour from polluting the analytical column. The 8 pesticides (4 triazines and 4 ureas) are determined by this method, the linearity is improved using 2 Fisher test. The detection and the quantification limits are a lso determined for each compounds and are less than 0.10 μg/L which is the limit fixed by the ECC reglementation on drinking water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.