Abstract

An attempt was made to establish a method for the simultaneous determination of urinary concentrations of phenol, o-, p- and m-cresols, 1 and 2-naphthol and xylenol isomers by capillary gas chromatography. Urine samples were extracted after acid hydrolysis of glucuronides and sulfates by solid-phase extraction. The ten substances were separated gas chromatographically using a capillary column (Ultra 2) of cross-linked 5% phenylmethyl silicone. Calibration graphs were linear for 5–100 μg/ml of all the phenols determined. The corresponding detection limits for phenolic compounds varied from 0.1 to 0.2 μg/ml. The relative standard deviations for samples in urine were in the range 2.6–16.6% and the accuracy was in the range 1.4–25%. Recoveries were generally over 80%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.