Abstract

A novel high-performance liquid chromatographic method for the determination of codeine, norcodeine and morphine in plasma and urine has been developed. The compounds were separated on a cyano column (15 cm×4.6 mm, 5 μm particle size) using a mobile phase of acetonitrile-triethylamine-distilled water (4:0.1:95.9, v/v) pH 3.1 and then determined by fluorescence detection. Calibration curves in the range 5–200 ng/ml for plasma and 0.1–10 μg/ml for urine were linear and passed through the origin. The imprecision and inaccuracy of the assay were less than 10% and the limits of detection were 2 ng/ml for all three compounds in human plasma.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.