Abstract

High performance liquid chromatography with diode array detector (HPLC-DAD) was developed for simultaneous determination of hesperidin, coptisine, palmatine, and berberine in HMC05, a standardized extract of eight different herbs. This method was validated in terms of specificity, linearity (r2 > 0.9995), precision (<5.0% RSD), and recoveries (96.6–110.5%). The LOD of these compounds were ranged from 101.6 to 171.7 ng. In addition, these four compounds in HMC05 were identified or tentatively characterized using HPLC-DAD-electrospray mass spectrometry (HPLC-DAD-ESI-MS).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.