Abstract

Edible plant oils are a key component of the daily human diet, and the quality and safety of plant oils are related to human health. Perfluorinated and polyfluoroalkyl substances (PFASs) are pollutants that can contaminate plant oil through the processing of raw materials or exposure to materials containing these substances. Thus, establishing a sensitive and accurate analytical method for the determination of PFASs is critical for ensuring the safety of plant oils. In this study, a method based on acetonitrile extraction and solid phase extraction purification combined with ultra-high performance liquid chromatography-triple quadrupole mass spectrometry (UHPLC-MS/MS) was developed for the simultaneous determination of 21 PFASs, including perfluorocarboxylic acids, perfluoroalkyl sulfonic acids, and fluorotelomer sulfonic acids, in edible plant oils. The chromatographic conditions and MS parameters were optimized, and the influences of the extraction solvents and purification method were systematically studied. Plant oil samples were directly extracted with acetonitrile and purified using a weak anion-exchange (WAX) column. The 21 target PFASs were separated on a reversed-phase C18 chromatographic column and detected using a triple quadrupole mass spectrometer with an electrospray ionization source. The mass spectrometer was operated in negative-ion mode. The target compounds were analyzed in multiple reaction monitoring (MRM) mode and quantified using an internal standard method. The results demonstrated that the severe interference observed during the detection of PFASs in the co-extracted substances was completely eliminated after the extraction mixture was purified using a WAX column. The 21 target PFASs showed good linearity in their corresponding ranges, with correlation coefficients greater than 0.995. The limits of detection (LODs) and limits of quantification (LOQs) of the method were in the range of 0.004-0.015 and 0.015-0.050 μg/kg, respectively. The recoveries ranged from 95.6% to 115.8%, with relative standard deviations (RSDs) in the range of 0.3%-10.9% (n=9). The established method is characterized by simple sample pretreatment, good sensitivity, high immunity to interferences, and good stability, rendering it suitable for the rapid analysis and accurate determination of typical PFASs in edible plant oils.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.