Abstract

Data from the Tsubota et al. (1993) experiments provided the basis for a numerical study that investigated the impact response of steel-plate lined, reinforced concrete panels using the SPH formulation in LS-DYNA. The simulated tests involved 50 mm (1.97 in), 70 mm (2.76 in), and 90 mm (3.54 in) thick reinforced concrete (RC) panels with steel liners and one 50-mm thick benchmark RC panel. Three of the five panels had a steel liner attached to the back face and one had a steel liner on both faces. The panels were normally impacted by a 39.6 mm (1.56 in) diameter projectile at a velocity of 170 m/s (6693 in/s). Reasonable predictions of observed damage, including perforation, liner fracture or bulging, and concrete scabbing were achieved using the MAT072R3 concrete material model. The effectiveness of adding steel liners to a concrete panel to prevent perforation and scabbing resulting from projectile impact was investigated using the numerical model and MAT072R3. Installing a steel liner on the back face of a panel, with a reinforcement ratio equal to that of the internal reinforcement, is an effective method to mitigate scabbing but has little effect on perforation resistance.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call