Abstract
Data from the Tsubota et al. (1993) experiments provided the basis for a numerical study that investigated the impact response of steel-plate lined, reinforced concrete panels using the SPH formulation in LS-DYNA. The simulated tests involved 50 mm (1.97 in), 70 mm (2.76 in), and 90 mm (3.54 in) thick reinforced concrete (RC) panels with steel liners and one 50-mm thick benchmark RC panel. Three of the five panels had a steel liner attached to the back face and one had a steel liner on both faces. The panels were normally impacted by a 39.6 mm (1.56 in) diameter projectile at a velocity of 170 m/s (6693 in/s). Reasonable predictions of observed damage, including perforation, liner fracture or bulging, and concrete scabbing were achieved using the MAT072R3 concrete material model. The effectiveness of adding steel liners to a concrete panel to prevent perforation and scabbing resulting from projectile impact was investigated using the numerical model and MAT072R3. Installing a steel liner on the back face of a panel, with a reinforcement ratio equal to that of the internal reinforcement, is an effective method to mitigate scabbing but has little effect on perforation resistance.