Abstract

Using a two-temperature hydrodynamic model, we analyze the regimes of multi-pulse laser ablation of aluminum by focusing on long-term plasma plume parameters. It is demonstrated that the plasma luminosity in single-, double- and multi-pulse ablation regimes may vary by two orders of magnitude. We also show that the double-pulse ablation regime with 5 J/ $$\hbox {cm}^2$$ fluence of each pulse and 100-ps inter-pulse delay is the most effective case giving rise to 250 times increase of the plasma brightness with respect to a single-pulse ablation regime with the same incident energy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.