Traction networks (TN) 25 kV generate higher electromagnetic fields (EMF) with frequency 50 Hz, whose strengths at a standardized height of 1.8 m, as a rule, do not exceed the permissible norms for electrical personnel. In places where railroads routes intersect with high voltage overhead power supply lines (OPL), interference of fields, generated by the traction network and OPL, occurs. This can lead to an increase in strengths and a complication of the EMF spatial structures. The article presents simulation results performed for a complex intersection, while 25 or 2 х 25 kV TN is crossed by a three-circuit 110-220 kV overhead power line at 90 degrees angle. Fazonord software application was used for simulating EMF strengths in points of traction networks and OPL intersection. Based on modeling results the following conclusions have been made: at intersection points of 1х25 kV traction network with a three-chain 110 - 220 kV power transmission line, the electrical field strength does not exceed the value acceptable for electrical personnel and reaches 4.2 kV/m; at the intersection with 2 х 25 kV traction network, this parameter decreases to 2.7 kV/m; the maximum amplitude of the magnetic field at the intersection points increases slightly.
Highlights
High-voltage overhead power lines (OPL) and electrified AC 25 kV railroads are sources of industrial frequency electro-magnetic field (EMF)
Electromagnetic fields with high strength levels can generate interference causing disturbances of electrical and electronic devices' normal functioning [1,2,3,4] and result in serious accidents when operations are conducted on disconnected power supply lines or communication lines when personnel is subject to induced voltage. 25 kV traction networks (TN) generate higher electromagnetic fields (EMF) with frequency 50 Hz, whose strengths at a standardized height of 1.8 m, as a rule, do not exceed the permissible norms for electrical personnel
Fazonord software application [15] designed in Irkutsk State Transport university, combines possibilities for modes simulation in phase coordinates and simultaneous calculations of EMF strengths
Summary
High-voltage overhead power lines (OPL) and electrified AC 25 kV railroads are sources of industrial frequency electro-magnetic field (EMF). Electromagnetic fields with high strength levels can generate interference causing disturbances of electrical and electronic devices' normal functioning [1,2,3,4] and result in serious accidents when operations are conducted on disconnected power supply lines or communication lines when personnel is subject to induced voltage. In places where rail-roads routes intersect with high voltage overhead power supply lines (OPL), interference of fields, generated by the traction network and OPL, occurs. This can lead to an increase in strengths and a complication of the EMF spatial structures [4]. This article is a further development of ideas represented in work [16], which performs a detailed analysis of electro-magnetic field structure at a point of overhead power line and a railroad perpendicular intersection
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.