Abstract

To validate models relevant to the transitional in-core 3-D power behavior, the 3-D core kinetics code SIMULATE-3K was applied to an analysis of one-pump trip test performed in a BWR-5 plant which includes large distortion of the power distribution due to the local insertion of control rods. The core boundary conditions required by SIMULATE-3K were calculated by the plant system analysis code RETRAN-3D. It was found that the transitional APRM signal and LPRM signals calculated by SIMULATE-3K agreed well with the measured data. The results showed that the transitional in-core 3-D power behavior can be appropriately predicted by SIMULATE-3K.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.