Abstract
Two-stage light-gas guns allow to accelerate projectiles up to velocities of several kilometers per second to conduct impact experiments. The projectile acceleration is obtained through a mechanism that relies on the expansion of a light gas, such as helium or hydrogen. Hydrogen allows to employ higher projectile velocities and masses than helium, together with lower wear of the launch tube. However, its use requires a thorough assessment of potential risks of explosion. In this work, we present a combined blast and structural numerical analysis to evaluate the effects of hydrogen deflagration as a consequence of accidental leakage scenarios during the operation of a two-stage light-gas gun. As a test case, we study the Large Gun operated at Fraunhofer EMI in Freiburg, Germany. The possible failure of non-structural elements, such as doors and windows, and the subsequent blast propagation into areas adjacent to the room hosting the facility are also accounted for. The simulation procedure presented in this work is scalable to similar and larger facilities for impact research as well as to other contexts involving analogous risks of gas explosions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Loss Prevention in the Process Industries
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.