Abstract

Theoretical work has illustrated that highly infrared transparent plastic films are well suited for use as intermediate glazings when used in conjunction with a low emissivity coating. Prototype glazing systems that incorporate low emissivity coatings and Teflon films were constructed. The thermal resistance of each of these prototypes was measured using the University of Waterloo Natural Convection Apparatus. Simulation of the glazing systems was carried out using a two-band glazing system thermal analysis program called VISION. Comparison between measurement and simulation showed good agreement. It can be concluded that highly infrared transparent intermediate glazings can be useful when high thermal resistance is desired and that the VISION glazing system analysis program is useful not only for parametric and sensitivity investigations but can also be used with confidence to estimate U-values of specific glazing systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.