Abstract

This study simulates and assesses the hydraulic features and residual chlorine in Al-Najaf city’s water supply network using WaterGEMS. Field and laboratory work was done to determine pressure heads, velocities, and chlorine residual. Constructed model was validated using field data. Values of RMSE were between 0.08 and 0.1, and 0.05 and 0.06 for pressure and residual chlorine, respectively. The examination of water distribution system (WDS) during peak demand hours indicated that the pump unit’s capacity could not meet the high-water demand, resulting pressure loss with values between 0.1 and 2 bar. Simulated residual chlorine levels ranged between 0.45 and 0.8 ppm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.