Abstract

The proposed magnetized Iron CALorimeter detector (ICAL) to be built in the India-based Neutrino Observatory (INO) laboratory aims to study atmospheric neutrinos and its properties such as precision measurements of oscillation parameters and the neutrino mass hierarchy. High energy charged current (CC) interactions of atmospheric neutrinos with the rock surrounding the detector produce so-called “rock muons” along with hadrons. While the hadron component of these events are absorbed in the rock itself, the rock muons traverse the rock and are detected in the detector. These rock muon events can be distinguished from cosmic muons only in the upward direction and can provide an independent measurement of the oscillation parameters. A simulation study of these events at the ICAL detector shows that, although reduced in significance compared to muons produced in direct CC neutrino interactions with the detector, these events are indeed sensitive to the oscillation parameters, achieving a possible 1σ\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$$1\\sigma $$\\end{document} precision of 10% and 27% in determining Δm322\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$$\\varDelta m_{32}^2$$\\end{document} and sin2θ23\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$$\\sin ^2\ heta _{23}$$\\end{document}, respectively. Hence a combination of the standard atmospheric neutrino analysis which is the main goal of ICAL, with these rock muon events, will improve the precision reach of ICAL for these parameters.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.