Abstract
This paper presents a simplified control strategy of SVPWM with a three segment switching sequence and 7 segment switch frequency for high power multilevel inverter. In the proposed method, the inverter switching sequences are optimized for minimization of device switching sequence frequency and improvement of harmonic spectrum by using the three most derived switching states and one suitable redundant state for each space vector. The proposed 3-segment sequence is compared with conventional 7-segment sequence similar for five level Cascaded H-Bridge inverter with various values of switching frequencies including very low frequency. The output spectrum of the proposed sequence design shows the reduction of device switching frequency and states current and line voltage. THD this minimizing the filter size requirement of the inverter, employed in industrial applications. Where sinusoidal output voltage is required<em>.</em>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Advances in Applied Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.