Abstract

This paper presents a simplified control strategy of spacevector pulse width modulation technique with a three segment switching sequence and seven segment switching sequence for high power applications of multilevel inverters. In the proposed method, the inverter switching sequences are optimized for minimization of device switching frequency and improvement of harmonic spectrum by using the three most desired switching states and one suitable redundant state for each space vector. The proposed three-segment sequence is compared with conventional seven-segment sequence for five level Cascaded H-Bridge inverter with various values of switching frequencies including very low frequency. The output spectrum of the proposed sequence design shows the reduction of device switching frequency, current and line voltage THD, thereby minimizing the filter size requirement of the inverter, employed in industrial applications, where sinusoidal output voltage is required.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.