Abstract
The loss of zero-voltage-switching (ZVS) of active switches has been a serious limitation of full-bridge (FBZVS) converters. Many techniques have been proposed in the past to extend the range of ZVS operation over the wider and also the full range of operation. However, in these techniques ZVS is achieved at the expense of additional conduction loss in active switches and losses in the auxiliary components. In this paper, the analysis for the additional losses in various full-range FBZVS DC-DC converters and their comparative evaluation is reported. Closed form expressions are derived for average value of device currents and losses. The loss curves for various topologies are plotted and compared. The analytical results are found to be consistent with the experimental efficiency tests performed on 500 W, 100 kHz prototype. It is concluded that a recently proposed new topology has the least penalty of additional losses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.