Abstract

Based on the authors' previous experimental studies of spray flash evaporation occurring in a superheated water jet ejected from a simple tubular nozzle into a low-pressure vapor zone, a simplified expression for the efficiency of flash evaporation, η, was derived asη=1- {1+kΔTs (t-t0)} -1where, k is an empirical coefficient, ΔTs the superheat of liquid at the nozzle exit, t the residence time of jet in the flash chamber and t0 the time lag of the initiation of flashing.It was realized that, for those cases in which bubble nuclei were sufficiently injected by electrolyzing warm feed water, the empirical coefficient k became practically independent of the nozzle diameter, the flow rate of liquid and the superheat of liquid at the nozzle exit, and increased up to 91s-1 K-1 on average at 60°C jet inlet temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.