Abstract

To avoid excessive slip of beam longitudinal bars at the joints of an earthquake-resisting moment frame, ACI 318 Building Code set a minimum joint depth of 20 times the diameter of the largest longitudinal beam bars passing through the joint, which is based on prior experimental verification of beam-column joints with Grade 420 MPa reinforcement. In view of that the 20-bar-diameter criterion cannot be simply extended for concrete frame joints with higher grade reinforcement, this paper summarizes international existing design criteria and proposes a simplified equation for the minimum joint depth. The equation applicability is assessed by evaluating the cyclic testing results of beam-column joints conducted in East Asian and Pacific Countries, where Grade 490, 590, and 690 MPa reinforcement have been used for earthquake-resistant concrete structures. Beam-column joints that satisfy the proposed equation can demonstrate satisfactory hysteresis behavior at an interstory drift of 4%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.