Abstract

In power factor correction (PFC) converters, achieving both good steady-state input current waveform and fast output dynamic response is a challenge. This is due to the effect of the double-line frequency ripple present in the sensed output voltage signal which tends to distort the reference current applied to the current controller, thus leading to a distorted input current waveform. Low bandwidth (BW) voltage loop designs to reduce this input current distortion make the output dynamic response very sluggish. A digital control algorithm for the estimation of the average value of the sensed output voltage is proposed in this study to achieve low total harmonic distortion input current and fast dynamic response with a higher BW voltage loop. The proposed algorithm is computationally less intensive and requires no additional sensors or circuitry. The effectiveness of the proposed control algorithm is validated through simulation and experimental tests on a 300 W boost PFC converter prototype operating in continuous conduction mode.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.