Abstract
A rapid and sensitive high-performance liquid chromatographic method for the analysis of cis and trans diastereomers of the anticoagulant rodenticide difenacoum has been described. The methodology demonstrates potential for the analysis of diastereomers of related 4-hydroxycoumarin anticoagulants. Separations were achieved by reversed-phase chromatography on a Zorbax ODS column with gradient elution using acetonitrile—water, modified with 0.1% acetic acid, as the mobile phase. Detection of the analytes was effected by fluoresence at excitation and emission wavelengths of 310 and 390 nm, respectively. Sample preparation from both plasma and liver has been simplified to reduce preparation time and manipulation. The minimum detectable concentration of each diastereomer was 5 ng/ml. Recoveries of 100% were obtained from plasma and 93% from liver tissue. This method has been used for the investigation of the pharmacokinetics of difenacoum diastereomers in rats, and for investigation of unexplained hypoprothrombinaemic events encountered clinically.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.