Abstract

Doppler-derived trans-prosthetic gradients are higher and the estimated effective valve area is smaller than the catheter-derived and directly measured hemodynamic values, mostly due to pressure recovery phenomenon. Pressure recovery to a varying extent is common to all prosthetic heart valves including bioprostheses. Pressure recovery-related differences are usually small except in patients with bileaflet metallic prosthesis, wherein high-pressure local jets across central orifice have been documented since long back and also in patients with narrow aortic root. We describe two patients with normally functioning stented aortic bioprostheses with supra-annular design (EPIC SUPRA and PERIMOUNT MAGNA), wherein very high trans-prosthetic gradients and critically reduced estimated effective valve orifice areas in presence of normal aortic size were consistently recorded over long periods of follow-up. The valve leaflets, however had normal excursion, were thin, opened with a triangular or oblong shape and had expected geometric valve area (1.7 and 1.6cm2 respectively) measured by 3D trans-oesophageal echocardiographic planimetry. Pressure recovery upstream the valves accounted for 20% and 12% of total pressure gradients respectively. Dominant site for pressure drop was intra-valvular (75–85%). Such a phenomenon has not been reported in vivo for these two valve designs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.