Abstract

A parameter adaptation method for a previously developed spark ignition (SI) to homogeneous charge compression ignition (HCCI) combustion mode transition control architecture is described. The goal of the adaptive method is to use transient SI–HCCI transition data gathered in online operation to tune the controller model parameters on a cylinder individual basis, in order to improve the accuracy of the controller's model-based calculations and account for cylinder to cylinder variability and drifts over time. The parameter adaptation is implemented on an experimental engine in an indirect adaptive control structure where the model parameters of the SI–HCCI transition controller are updated based on real-time measurements and used in subsequent model-based calculations. Comparison of SI–HCCI transition responses before and after adaptation at a single operating condition shows notable benefits from use of the adaptive method. When tested at differing operating points, the performance of the adapted controller remains overwhelmingly favorable to that of the baseline controller even when conditioned on data from only a single operating point.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.