ABSTRACT ASHUNT line metering system with segmental orifice provides a low cost means of cumulatively measuring the volume of water discharged from irrigation wells. The flow through the shunt line, which is measured by a small household type water meter, is related to the flow through the main irrigation pipe by a flow coefficient which was experimentally determined for a 15.41 cm (6 in.) pipe. This flow coefficient is a function of the degree of orifice contraction. Field installation is relatively easy and field calibration is unnecessary. The cost of the metering system can be less than $100 and the accuracy is within 5 percent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.