Abstract
Abstract Funding Acknowledgements Type of funding sources: Other. Main funding source(s): This work was supported by the Ministry of Science and Higher Education grant (Russian Federation President Grant) #MD-2314.2020.7. Background/Introduction. Radiofrequency ablation (RFA) is the mainstay of invasive management of atrial fibrillation (AF). Amongst a variety of performance indicators, interlesion distance (ILD) has a potential to become a guiding one. Uptodate clinical AF RFA protocols suggest that ILD has to be less than 6 mm, however the research is still lacking in regard to its actual targeted value. Purpose. The aim of the research is to study a relationship between ILD and first-pass isolation (FPI) in ablation-index guided AF ablation procedures. Methods. This was a prospective observational multicenter study. Data were derived from the web-based system. Pulmonary veins (PV) isolation procedures were performed according to the local practice, and RFA settings depended on operators’ preferences. A total of 446 patients were enrolled, 407 of them underwent first-time AF ablation, data on ILD available in 322 subjects (177 (55%) males, mean age 62 ± 9 years old, 259 (80%) with paroxysmal AF). A mean ILD was calculated manually in each case as a sum of all ILDs divided by number of ablation tag points. FPI was considered in cases when no additional applications were required for bidirectional PV block following creation of a one circle around ipsilateral PVs and after a 20-min waiting period. Patients were divided into two groups according to ILD (Group 1 ILD≤ 4 mm, 163 patients and Group 2 ILD > 4m, 159 patients) post-procedurally. Results. The mean procedure time was 102 ± 52 min, the median fluoro time was 9 min [IQR 6; 15]. The following VisiTag parameters were used: the median target ablation index 400 [IQR 400; 500] on the left atrial anterior wall and 380 [IQR 380; 400] on the posterior segments, the median minimal contact force 3g [IQR 3; 4], median minimal time per a point - 4 sec [IQR 3; 15], mean catheter stability 3 mm (ranged between 2.5 and 3 mm). In 261 (81%) cases operators used 3 mm ablation tag size, and in 19% - 2 mm. The mean ILD was 4,1 ± 1,0 mm (3,2 ± 0,5 mm in Group 1 vs 4,6 ± 0,5 mm Group 2). FPI was achieved in 189 (59%) cases. In the "ILD ≤ 4 mm" group FPI was achieved in 93 (49,2%) cases and there were 96 (50,8%) cases of durable FPI in the "ILD >4 mm" group (χ2 = 2,4, p = 0,124). The mean procedure time was 111 ± 46 min and 100 ± 35 min in Group 1 and 2 (p = 0,01), respectively. The mean fluoro time was 13 ± 4 min and 11 ± 4 min in Group 1 and 2 (p = 0,08), respectively Conclusion(s). The results of our multicenter study suggest that shortening of the distance ≤4 mm has no effect on the achievement of first-pass PV isolation, but required more procedure and relatively more X-ray exposure time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.