Abstract

Abstract Introduction The CLOSE protocol is a novel contact-force guided technique for enclosing pulmonary veins in patients with atrial fibrillation (AF). Consistency and lesion contiguity are essential factors for procedural success. We sought to determine whether left atrial (LA) wall thickness (LAWT) and pulmonary vein (PV) dimensions as assessed by coronary CT angiography (CTA) could influence the efficacy of successful first-pass isolation using the CLOSE protocol. Methods In a single center, prospective study we enrolled 94 patients with symptomatic, drug-refractory AF who underwent pre-ablation left atrial CTA and initial radiofrequency catheter ablation between 2019.01–2020.09. The LA was divided into 11 regions when assessing LAWT. Additionally, the diameter and area of the PV orifices were obtained. First pass isolation was recorded separately for the right and left PVs. After the first pass ablation circles were ready, additional ablations were applied in those cases where first pass isolation was not achieved, to reach complete PV isolation. Predictors of successful first pass isolation were determined using logistic regression models that included anthropometrical, echocardiographic and CTA derived parameters. Results A total of 94 patients were included in the analysis with mean CHA2DS2-VASc score of 2.1±1.5 (mean age 62.4±12.6 years, 39.5% female). 61.7% were paroxysmal, 38.3 were persistent AF patients. Mean procedure times were 81.2±19.3 minutes. Complete isolation of all four PVs was achieved in 100% of patients. First-pass isolation rate was 76%, 71% and 54%, for the right PVs, left PVs and all four PVs, respectively. No difference was found regarding comorbidities and imaging parameters between those with and without first pass isolation. LAWT (mean of all 11 regions or separately) had no effect on the procedural outcome (all p>0.05). Out of all assessed parameters, only RSPV diameter was associated with right sided successful PVI on first pass isolation (p=0.04, OR 1.01). Conclusion The use of CLOSE protocol in AF patients resulted in high periprocedural success rate in terms of first pass isolation, independently from the thickness of the LA wall. RSPV diameter could influence the results of first pass isolation. Funding Acknowledgement Type of funding sources: None.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.