Abstract

The shock response of poly[methyl methacrylate] (PMMA) acquired from two providers, Spartech and Rohm & Haas, has been measured to investigate the shock response variations related to material pedigree. These measurements have also been used to examine the effects of viscoelasticity on Spartech PMMA. Measurements of the Hugoniot curves, release wave speeds, and index of refraction have been acquired up to previously unexplored stresses, ∼10.7 GPa, for Spartech PMMA. In-situ, time-resolved particle velocity wave profiles, as a function of time and depth, were obtained using twelve separate electromagnetic gauge elements embedded at different depths in the PMMA. A comparison of the new data to the shock response data for Rohm and Haas PMMA, used as a “standard” material in shock compression studies, shows that there are no significant differences in shock response for the two materials. From the index of refraction measurements, the apparent particle velocity correction for a PMMA window exhibits an interesting oscillation, increasing at up = 0.3 km/s after decreasing up to that point. The results are generalized into guidelines for sourcing PMMA for use in shock studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call