Abstract

An in-pile test program for the development of a high burn-up fuel is planned for the HANARO reactor. The source term originates from a leakage of fission products from the anticipated failed fuels into the gas flow tubes and around the instrumentation and control system. In order to quantify the fuel composition in the event of a fuel failure, the isotope generation and depletion code ORIGEN 2.0 was used. The computer program Microshield 6.2 was used to calculate the doses from specific locations, where a high radioactivity is expected during an irradiation. The results indicate that the equivalent dose in the investigated working areas is less than the permitted dose rate of 6.25 μSv/hr. However, access to the area of a decay vessel may need to be limited, and the installation of a Pb wall with a 20.5 cm thickness is recommended. From the analysis of a radioactive decay with time, most of the concerned gaseous nuclides with short half-lives after 3 months, were decayed, with one exception which was Kr-85, thus it should be released in accordance with applicable government laws after measuring its activity in individual holding vessels.