Abstract

A double helical-like flow heat exchanger model was built, its shell-side flow state was studied by the CFD method, and the difference in heat transfer performance between it and the torsional flow heat exchanger was compared. From the numer?ical simulation results, it is found that the heat transfer coefficient and pressure drop are improved by 7.07-8.93% and 15.50-18.22%, respectively at the same flow rate, and the comprehensive performance expressed as Nu/f 1/3 is improved by 21.84-24.08%. Using the orthogonal test method to optimize the shell-side struc?ture, it is found that the comprehensive performance is influenced by the two factors of spacing/groups and angle of baffles, and the influence of the deflection angle of two adjacent groups of baffles is very small, and the optimal structural combi-nation of comprehensive performance is 30-0-70/11 (the angle of baffles is 30?, the deflection angle of two adjacent groups of baffles is 0?, the spacing between two adjacent sets of baffles is 70 mm, and the number of baffle groups is 11). The reliability and feasibility of the simulation method were verified by experiments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.