Abstract

This paper presents the FE analysis of the influence of different parameters on the shear resistance of panels with different arrangements of longitudinal stiffeners. The studied parameters were the stiffener bending stiffness, the panel aspect ratio, the stiffener position, the web slenderness and the flange rigidity. Longitudinal stiffeners of trapezoidal shape were compared to open T-stiffeners. The former proved to be more efficient, since a larger panel resistance is achieved, for which in addition a smaller stiffness of trapezoidal stiffeners is needed. Different features of the new Eurocode rules were verified against the FEA results as well. Three different procedures for the determination of panel slenderness were tested and the reduction of stiffener bending stiffness, prescribed due to a better correlation with tests on open stiffeners, was verified for both closed and open stiffeners. The influence of bending moment was also considered and the verification of shear and bending interaction was discussed. Finally, the flange contribution to shear resistance was critically analysed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.