Abstract

The shear performance of bolted rock joints under cyclic loading condition was studied through laboratory shear tests. The tests were performed on a cyclic shear testing apparatus. The fully encapsulated rock bolts were inserted in the rock joints. The upper block was fixed in the horizontal direction, and the cyclic shear load was applied laterally on the lower block. A total of 16 shear tests were conducted for two types of rough joints. The results showed that the failure mode of rock bolts in cyclic shear test was different with the case of direct shear test. When the cyclic displacement was small, the rock bolt played a very small role in the second-to-fifth cycles, the rock bolt remained unbroken during cyclic shearing. The shear resistance of the rock bolt would gradually recover after the shear displacement has exceeded the cyclic displacement in the termination cyclic after five cycles. When the cyclic displacement was large, the rock bolt broke during cyclic shearing, and the shear resistance could not be recovered in the termination cyclic. It is indicated that the rock bolt had completely lost its supporting role after cyclic shear loading. The shear strength reduction of bolted joints under the cyclic loading condition was much significant compared to the un-bolted joints. Therefore, the influence of cyclic loading on the shear resistance of the rock bolt was much larger than its counterpart of the rock joint itself. These results showed that the shear performance of a rock bolt inserted in a rock joint was strongly influenced by cyclic shear loading.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call