Abstract

An experimental study was carried out to investigate the shear behavior of corrugated metal ties anchoring brick veneer walls to light wood frame backing. Connection subassemblies were tested under monotonic and cyclic shear, simulating in-plane loading of veneer wall systems, and statistical analyses were conducted to identify and quantify the parameters influencing their behavior. Force-displacement curves obtained under monotonic loading can be considered an upper bound for the hysteresis loop envelopes. Fastener slippage during cyclic loading enabled by the localized damage of the surrounding wood fibers diminished the energy dissipation capacity of the connection and caused pronounced pinching in the hystereses. When corrugated ties with minimum thickness permitted by the Masonry Standards Joint Committee (MSJC) Code were considered under in-plane loading, tie design and bend eccentricity were found to be the most important factors, while tie location in the bed joint, fastener type, and fastener qua...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.