Abstract

This study evaluated the shaping ability of XP-endo Shaper and Mtwo systems in long-oval-shaped canals of extracted human mandibular molars using micro-computed tomography (micro-CT). Images recorded before and after preparation were evaluated for morphometric measures regarding increase in canal volume, dentin removed, surface area, untouched walls and structure model index (SMI). Data were statistically analysed using the Mann-Whitney test with 5% of significance. On both groups, the root canal preparation significantly increased all analysed parameters (P > 0.05). There was no statistical difference between XP-endo Shaper and Mtwo systems in the increase of the canal volume (30.50%-27.82%), in volume of dentin removed (2.77%-2.40%), in the increase of the canal surface area (11.30%-8.86%), in canal untouched surfaces (9.57%-8.51%) and in the SMI (2.59%-2.68%), respectively. XP-endo Shaper and Mtwo systems showed similar shaping efficiency and were not able to completely prepare the walls of long-oval-shaped canals of extracted human mandibular molars.