Abstract
AbstractThis paper presents the shake-table tests of a full-scale, two-story, reinforced masonry shear-wall structure designed by a displacement-based method. The test structure had two T-sectioned and one rectangular-sectioned wall components along the direction of the table motion, and four rectangular-sectioned wall components in the orthogonal direction. The structure was subjected to a series of dynamic tests with a historical ground motion record scaled to intensity levels up to that of the maximum considered earthquake (MCE). The structure formed a soft-story mechanism during the last test. The recorded displacements were within the target limits for the design earthquake-level table motion, but exceeded the target limits for the MCE level. Although the structure experienced severe damage and incurred diagonal cracking in wall components with low aspect ratios, it did not collapse. The comparison of the analysis results to the test results shows that the walls in the orthogonal direction had a sign...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.