Abstract

The calculation methods on the base of the concentrated parameters models, which were formed in the XX century, allowed to get simple and theoretically consistent solutions for the problems of one-layered building partitions sound insulation finding. The sound insulation estimation for the double-layered massive building partitions also is of scientific and practical interest, as double layer partitions are the particular case of the single layer enclosure's application. The concept of concentrated parameters includes the concentrated and the reduced masses, as well as the concentrated elasticity. The criteria for the object application as a specified kind of the concentrated parameters in the acoustical problems is the presence or the absence of the oscillation movement in it. The three calculation models with the application of the concentrated (discreet) parameters that to define the sound insulation of the massive double layer enclosures are given. The equations for sound insulation computation for one layer partition are represented. They were derived on the base of momentum law and energy conservation formulas under the continuity of energy flow conditions at the interface of different media. The three main paths of sound propagation from the room with the air-borne noise to the isolated room are shown. The two frequency range are separated on the way of the direct sound propagation: at the first, the surface density of the one of two layers and the air elasticity in the inter-layer gap influence on isolation; at the second one, the predominant role belongs to the summarized insulation by the "Mass Action Law" of the two layers. The indirect way's insulation is taken in account through the additional sound insulation graph drawing. The compound insulation curve is defined by the ways, where the sound energy transmittance is maximal at the standard frequency spectrum. The method of sound insulation calculation for the double layer partitions on the base of the concentrated parameters model application is revealed. As an example, the calculation of a prefabricated double layer inter-flat wall in the panel building was performed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.