Abstract

This study aims to determine the service load capacity of existing truss construction using the wood material. Analysis and calculations were performed on tensile members, compression members,connection, and deflections that occur using the standard SNI 7973 : 2013. The existing truss construction needs to be analyzed for its overall strength so that the function of the building can be maximized. The results of the research on the existing truss construction obtained that the value of the truss construction capacity in carrying the service load was due to the strength of the connection with a service load of 350 kgf/m. The deflection that occurs is 35.5 mm, far beyond the maximum deflection of 7.14 mm, so it is necessary to repair the connection by increasing the number of connecting devices or replacing the connection tools using bolts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.