Abstract

An immune adherence hemagglutination (IAHA) test for the measurement of antibodies to Legionella pneumophila was developed and evaluated for the diagnosis of Legionnaires disease. Its sensitivity was compared to that of the indirect fluorescent antibody (IFA) test and a recently developed indirect hemagglutination (IHA) test. The sensitivity of the three tests appeared to be similar, with the IFA test giving slightly higher titers. Both the IHA and IAHA tests appear useful for the serodiagnosis of Legionnaires disease; the IAHA test has the advantage that it can be used with many other serological antigens.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.