Abstract

Two reversed-phase HPLC methods were developed for the quantitative determination of the two components of the novel vaccine adjuvant IC31. The adjuvant consists of a mixture of a synthetic oligodeoxynucleotide (ODN) and an 11-mer cationic peptide. The negatively charged oligodeoxynucleotide and the positively charged peptide form a complex that has to be quantitatively dissociated for analysis. Dissociation of the complex was achieved with a basic heparin solution (1000 IU/ml) when analyzing the ODN, whereas 30% acetic acid was used for the determination of the peptide. Both methods are suitable for identification and quantification but also for stability indicating investigations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.