Abstract

As a key component in a phase-shifting interferometer, the optical flat is often affected by supporting methods and generates deformation. In this paper, we propose a method to separate the deformation error through rotation measurement and Zernike polynomial fitting. We studied the principles, simulations, and experiments of this method. First, a support model is established in Comsol, and the deformation of the optical flat is analyzed. Then, the numerical simulation of the separation method for the deformation is performed, and the corresponding experiment is carried out on a Φ300 mm vertical Fizeau interferometer to verify the correctness of the method. The results show that numerical calculation and experimental measurement results are in good agreement, the difference between the PV value and the RMS value are only 0.004λ and 0.002λ, respectively. Finally, the error term that affected the calculation accuracy was analyzed. This proves that the proposed method can effectively separate the deformation introduced by the support.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.