We propose an optimizing method to improve the sensitivity of bimetallic film surface plasmon resonance (SPR) sensor based on wavelength and angular combined modulations. The incident angle and thickness of transducing layer are optimized in terms of a variation range of refractive index, instead of one given value of refractive index. This method can reduce the SPR dip for the whole variation range of refractive index and maintain high sensitivity simultaneously. The theoretical results show that the highest sensitivity can achieve 22,000 nm/RIU, which is almost twice larger than the results without optimization under the same condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.