Abstract
Abstract An approach for better understanding of the physical implication of estimated aquifer parameters is demonstrated by analysing the pumping test data at Cottam in the Nottingham aquifer, UK. A sensitivity analysis showed that the area represented by the estimated parameters was much smaller than the area covered by the depression cone. After parameters are estimated, further research should be carried out to understand what portions of the aquifer the parameters represent. The parameters estimated at Cottam represented mainly aquifer features between roughly 100 and 2000 m. The sensitivity analysis also showed that the observed drawdown being satisfactorily matched by a model with uniform parameters does not prove that the aquifer is homogeneous. Slightly anomalous data may imply the existence of large anomalous zones. Although the drawdowns at Cottam could be ‘satisfactorily’ fitted by a model with uniform parameters, the fit could be improved by a model using a more permeable aquifer but with a z...
Published Version (Free)
Talk to us