A novel voltammetric method applying a semi-circular potential sweep is applied to the simultaneous electroanalytical determination of solutions containing two components with similar oxidation potentials which precludes their resolution using conventional voltammetric methods including linear sweep, square wave and pulse voltammetries. Three such biologically important mixtures, ascorbic acid/acetaminophen, glucose/ethanol and hydroquinone/catechol were studied, analytical methods developed and the method of semi-circular sweep voltammetry shown to give notable advantages over the other conventional analytical voltammetries in terms of signal resolution and the sensitivity of the detection. Favourable accuracy was obtained using electrodes with either simple or no modification in the established linear detection ranges.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.