Abstract

The feasibility of hybrid -fiber-reinforced-polymer rods that demonstrate the important safety features of self-monitoring capability and pseudo-ductility is demonstrated. The rods are intended to be the basis of improved pultruded reinforcements for concrete or other civil applications where safety is of critical importance. The lowest elongation fiber in the seven rods investigated is carbon, which by virtue of its piezoresistivity allows the monitoring of deformation and fracture throughout an entire rod with simple electronic equipment. Resistance measurements obtained during quasi-static tests clearly reveal failure of the carbon fibers. Following this easily detected event, higher loads can be safely sustained by the remaining high-elongation fibers if the carbon tows are dispersed in the cross-section rather than concentrated in one location.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.