Abstract

AbstractA simple flow-based method was developed for the simultaneous separation of certain transition metal ions (Co, Ni, Cu, Zn, Cd) from aqueous systems, which ions show ecotoxic effects when present at elevated concentrations. A silica-gel-bonded macrocycle system, commonly known as molecular recognition technology (MRT) gel, was used for solid phase extraction (SPE) of the target analytes. The collection behavior of the MRT-SPE system was studied based on pH. Fortified deionized water samples containing 250 µg L−1 of each of the elements were treated at the flow rate of 1 mL min−1. The collected analytes were then eluted by 3 M HNO3 and analyzed using inductively coupled plasma spectrometry. Detection limits of the proposed technique were in the range of 0.004–0.040 µg L−1 for the studied metal ions. The validity of this separation technique was checked with spiked ‘real’ water samples, which produced satisfactory recoveries of 96–102%. The non-destructive nature and highly selective ion-extraction capability of the SPE material are the most important aspects of the proposed method and they are the main focus of this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.