Abstract

Concerning the selective recovery of minor trivalent actinides (MA(III) = Am(III) and Cm(III)) from high level liquid waste (HLLW) by extraction chromatography, adsorption and elution behaviours of MA(III) and fission products (FP) in a nitric acid media were studied using iHex-BTP/SiO2-P adsorbents, which is expected to show high adsorption affinity for MA(III) even in concentrated HNO3 solution, such as HLLW. In the batch experiments, Pd showed strong adsorption on iHex-BTP/SiO2-P adsorbents under any concentration of HNO3. The MA(III) and heavy Ln(III) (Sm(III), Eu(III) and Gd(III)) were also adsorbed at the condition of high HNO3 concentration, but they showed no adsorption under low HNO3concentration. The separation factor for MA(III)/heavy Ln(III) took the maximum value (over 100) at around 1mol/dm3 HNO3. It was difficult to elute MA(III) or heavy Ln(III) selectively by HNO3 from the iHex-BTP/SiO2-P adsorbents degradated by γ-ray irradiation. The chromatographic separation of real HLLW by an iHex-BTP/SiO2-P column showed that MA(III) could be recovered selectively by adjusting the acidity of the feed solution, i.e. HLLW, to 1mol/dm3 and using H2O as eluant. The adsorption of Pd(II) can be decreased by the addition of appropriate complexing reagents, e.g. DTPA, into HLLW without any effects on the MA(III) adsorption.