Abstract

A selective pressurized liquid extraction technique (SPLE) was developed for the analysis of polychlorodibenzo-p-dioxins, polychlorodibenzofurans (PCDD/Fs) and dioxin-like polychlorobiphenyls (dl-PCBs) in clam and crab tissue. The SPLE incorporated multiple cleanup adsorbents (alumina, florisil, silica gel, celite, and carbopack) within the extraction cell. Tissue extracts were analyzed by high resolution gas chromatography coupled with electron capture negative ionization mass spectrometry. Mean recovery (n = 3) and percent relative standard deviation for PCDD/Fs and dl-PCBs in clam and crabs was 89 ± 2.3 and 85 ± 4.0, respectively. The SPLE method was applied to clams and crabs collected from the San Jacinto River Waste Pits, a Superfund site in Houston, TX. The dl-PCBs concentrations in clams and crabs ranged from 50 to 2,450 and 5 to 800 ng/g ww, respectively. Sample preparation time and solvents were reduced by 92 % and 65 %, respectively, as compared to USEPA method 1613.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.