Abstract
Since the Japanese Building Standards Act was revised in 2000, the installation of steel timber connectors (STCs) to reinforce timber frame (TF) connections has been mandated for new-build TF houses in Japan. However, for the TF houses built before then, more than 40% do not have sufficient STCs and are considered earthquake-prone. This study proposed a simple and easy seismic retrofit technique for such earthquake-prone existing houses. The proposed technique can reinforce TF connections using only plywood and common nails and achieve equivalent performance to the benchmark STCs used in Japanese TF houses, such as the “CP-T type” or the combination of “VP type” and “BP type” STCs. Experiments were performed to compare the proposed technique with the STCs using pullout and full-scale in-plane cyclic tests. The experimental results showed that the proposed technique had a higher seismic performance than the STCs, which was particularly excellent in displacement ductility to prevent a collapse of the TF house without damaging the timbers. The proposed technique will be accepted by many carpenters when retrofitting earthquake-prone existing houses because simple and easy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.