Abstract
Full-scale dynamic testing of suspended ceiling systems was performed to obtain fragility data suitable for performance-based assessment and design. On the basis of the fragility data derived from testing, (1) the use of retainer clips improves the performance of ceiling systems in terms of loss of tiles, (2) including recycled cross tees in the suspension grid increases the vulnerability of the ceiling systems, (3) undersized (poorly fitting) tiles are substantially more vulnerable than properly fitted tiles, and (4) the use of compression posts improves the seismic performance of ceiling systems for the limit states of minor and moderate damage. Fragility curves are provided for four damage states.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.