Abstract
In this two-part work, seismic behavior and design of steel moment frames with masonry infills are investigated systematically. In this first part, the “infill strength ratio” (the ratio of the story shear strength of infills to the story shear strength of the bare frame) is shown to have a fundamental effect on the seismic behavior of an infilled frame. This fundamental effect is demonstrated using pushover analysis of an example steel moment frame with masonry infills in uniformly infilled and open ground story configurations. In general, infill strength ratios greater than about 0.35 are associated with progressive deterioration of seismic performance, leading to story mechanisms concentrated in the lower stories. Greater infill strength ratios can also lead to local shear failures in frame members.