Abstract

AbstractThis paper presents the experimental results of a study investigating the effectiveness of using externally bonded fiber-reinforced polymer (FRP) tow sheets for in-plane bending strengthening and repair of reinforced concrete (RC) shear walls. The repair/strengthening scheme is designed to enhance the flexural load-carrying capacity of the walls and prevent brittle shear-related failures. The experimental program consisted of the performance evaluation of the FRP system in seven RC shear wall specimens tested to failure under lateral loads. The effectiveness of two different anchoring systems to transfer the loads carried by the FRP sheets to the supporting elements of the wall was also investigated. The experimental results showed that the FRP system was successful in restoring (in repair applications) and increasing (in strengthening applications) the initial stiffness and ultimate load-carrying capacity of the walls, while maintaining a ductile response behavior and avoiding brittle shear failu...

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call